Object

Title: The method of quantitative analysis of cysteinyl leukotrienes in urine based on mass spectrometry

Abstract:

Cysteinyl leukotrienes cause many pathophysiological efects: bronchial hyperreactivity and bronchospasm, increased microvasculare permeability, mucous secretion. Reliable and reproducible estimation of cysteinyl leukotrienes biosynthesis is useful in detection and evaluation of diseases and also in monitoring of treatment’s efficcacy. The aim of this work was to develop, characterize and validate a new method of quantitative analysis of LTE4, and to test its practical application among patients with asthma, ischemic heart disease and healthy subjects. The method of quantitative analysis of cysteinyl leukotrienes in urine based on immunoaffinity extraction and mass spectrometry and was successfully developed and proved useful in clinical research. The method provides reliable and reproducible results of LTE4 measurement. The assay range is 6.7-2000 pg LTE4/ml of urine and the detection limit is 3.3 pg/ml. In the group of 50 healthy adults the mean uLTE4 concentration is 32.72 ± 25.10 pg/mg of creatinine. The range of reference values of LTE4 in urine is 5.69 – 119.42 pg/mg of creatinine. Among patients with ischaemic heart disease, whom percutaneous coronary intervention was performed, an increase of average 40% uLTE4 concentration within first hours after the procedure was noted. During investigation based on 110 observations of patients with coronary artery disease it was show ; n that zileutone decreased on average 30% the production of leukotrienes. In addition, increased systemic biosynthesis LTE4 was documented by uLTE4 excretion measurements in the group of 38 asthmatic patients. A distinct phenotype of bronchial asthma – aspirin-sensitive asthma, was found to correlate with elevated concentration of LTE4 in urine, by comparison with asthmatics who tolerated aspirin well.. Results obtained by the method were compared the commercial immunoenzymatic (ELISA) Kit. On the basis of comparison results, LC/MS method of measurement of uLTE4 was found more accurate and precise than ELISA. LC/MS method should be also considered as very specific, and very reliable.

Place of publishing:

Kraków

Level of degree:

2 - studia doktoranckie

Degree discipline:

immunologia ; biochemia

Degree grantor:

Wydział Lekarski

Promoter:

Sanak, Marek

Date issued:

2008

Identifier:

oai:dl.cm-uj.krakow.pl:874

Call number:

ZB-109599

Language:

pol

Access rights:

nieograniczony

Object collections:

Last modified:

Jun 26, 2023

In our library since:

Nov 21, 2012

Number of object content hits:

379

Number of object content views in PDF format

140

All available object's versions:

http://dl.cm-uj.krakow.pl:8080/publication/874

Show description in RDF format:

RDF

Show description in OAI-PMH format:

OAI-PMH

Edition name Date
ZB-109599 Jun 26, 2023
×

Citation

Citation style:

This page uses 'cookies'. More information