Tytuł: Response to CRT in patient with chronic heart failure depending on the ventricular leads localization

Abstrakt:

The aim of the study was to assess how the response to CRT depends on ventricle leads localization, usefulness of radiological methods in prediction response to CRT and examination influence modified stimulator’s parameters on response to CRT. 50 consequence patients after CRT implantation were enrolled to the study. Horizontal separation was larger in the group of the patients who died (9,0 ± 1.8 cm vs 8,0 ±3,2 cm, p=0,0222). Significant correlation between LV lead’s segment in AP chest X-ray and LVESV was observed (r = 0,75, p = 0,030). Significant correlation between right lead segment in AP projection and narrowing of the QRS complex as well as change of LVESV were observed (r = -0,46, p = 0,022; r = -0,74, p = 0,037, ). In the lateral chest X-ray RV lead’s segment correlated with change of the QRS complex (r = -0,51, p = 0,010). There was correlation between narrowing of the QRS complex and absolute separation (r = -0,42, p = 0,036) and horizontal separation (r = -0,41, p = 0,044). LV EF increase was larger when RV lead was located in line 2 comparising to localization in line 3 or 4 (45,12 ± 28,5% vs 18,1 ± 31,6%, p = 0,0406), whereas QRS was narrower for line 3 and 4 comparising to line 2 (-19,3 ± 13,7 ms vs -6,8 ± 10,0 ms, p = 0.0122). Mean value of the left ventricle segment was higher in patient with decreased NT-proBNP plasma concentration (13,4 ± 2,4 vs 8,3 ± 2,3, p ; =0,036). 6-MWT distance was longer in the group with increased AV-delay (22,2 ± 15,4 % vs -10,1 ±29%, p = 0,0045). Conclusion: radiological methods of localization of the ventricular leads are a useful tool in prediction response to CRT, but results are ambiguous.

Miejsce wydania:

Kraków

Stopień studiów:

2 - studia doktoranckie

Dyscyplina:

choroby układu krążenia

Instytucja nadająca tytuł:

Wydział Lekarski

Promotor:

Czarnecka, Danuta

Data wydania:

2012

Identyfikator:

oai:dl.cm-uj.krakow.pl:3462

Sygnatura:

ZB-117135

Język:

pol

Prawa dostępu:

nieograniczony

Kolekcje, do których przypisany jest obiekt:

Data ostatniej modyfikacji:

26 cze 2023

Data dodania obiektu:

7 mar 2013

Liczba wyświetleń treści obiektu:

599

Liczba wyświetleń treści obiektu w formacie PDF

155

Wszystkie dostępne wersje tego obiektu:

http://dl.cm-uj.krakow.pl:8080/publication/3462

Wyświetl opis w formacie RDF:

RDF

Wyświetl opis w formacie OAI-PMH:

OAI-PMH

Nazwa wydania Data
ZB-117135 26 cze 2023
×

Cytowanie

Styl cytowania:

Ta strona wykorzystuje pliki 'cookies'. Więcej informacji